Difference between revisions of "End Effector Catalogue"

From Fab Lab Bcn WIKI
Jump to: navigation, search
(Vaccume end effector with single Suction cap)
Line 49: Line 49:
  
  
'''Total system power:''' 1,5 kW
+
'''Required parts:'''  
  
'''Power input:''' 230 V, 1Ph/N/PE/50-60Hz
+
Vacuum Generator / Union / Square
  
'''Fusing:''' 16 A
+
Suction Cup (coval VP15NBRIF18C)
  
'''External control 0 - 10 Vdc for rotary speed:''' optional
+
Pneumatic Push to Connect Fittings Male Straight | ∅ 8mm Tubing
 
+
'''Dimensions''' (LxWxH) : 720-780 x 340 x 790 mm
+
 
+
'''Hopper capacity''' 30 Litre, 44 Litre
+
 
+
'''Pump outlet size''' 1" GEKA PLUS
+
 
+
'''Filling height:''' 75 cm
+
 
+
'''Total weight:''' 33 kg
+
  
 
==Health & Safety==
 
==Health & Safety==

Revision as of 17:14, 27 June 2023

ABB IRB 120 (6 Axes Robot)


Motor Screw Extruder

700 × 402 pixels


Arduino Diagram

700 × 402 pixels


Connection to robot

700 × 402 pixels

elements, power supply inlet plug with undervoltage release to prevent re-start in case of voltage interuption

3- Hopper for wet premixed material

4- Housing with polyurethan inlet

5- Worm pump

6- Pump outlet with pressure gauge

Operating the machine

Connections Before Start-Up

Connect the main power plug to the control cabinet with the cable to the construction 230V/1/N/PE/50Hz (3x1,5mm2).

Make sure that all cables and safety devices are functioning properly.



Vaccume end effector with single Suction cap

700 × 402 pixels


Required parts:

Vacuum Generator / Union / Square

Suction Cup (coval VP15NBRIF18C)

Pneumatic Push to Connect Fittings Male Straight | ∅ 8mm Tubing

Health & Safety

- Always use safety glass while disconnecting the hose.

- Never run the machine dry, at least water is needed to operate the pump otherwise damage may occur.

- Never let the material fall below the minimum material level and always keep the screw under the material.

- Never disconnect the hose when there is any pressure in the pressure gauge.

Machine Views

700 × 402 pixels


1- Motor

2- Control system: Frequency converter with switch elements, power supply inlet plug with undervoltage release to prevent re-start in case of voltage interuption

3- Hopper for wet premixed material

4- Housing with polyurethan inlet

5- Worm pump

6- Pump outlet with pressure gauge

Operating the machine

Connections Before Start-Up

Connect the main power plug to the control cabinet with the cable to the construction 230V/1/N/PE/50Hz (3x1,5mm2).

Make sure that all cables and safety devices are functioning properly.

Start-up in manual mode

- Before Operating the machine check the machine state. Switch rightwards for manual mode.

700 × 402 pixels


- Step 1: Turn on the main switch

700 × 402 pixels


- Step 2: Fill the material-hopper with wet premixed material.

- Step 3: Turn the Forward/Reverse Switch to FWD (Start the machine by turning the mode switch from 0 to FWD)

700 × 402 pixels